日立GVF-III調試手冊

2021/7/24 13:41:49點擊:

日立GVF-III調試手冊

GVF-Ⅲ電梯安裝調試手冊

前 言
本資料介紹 GVF-Ⅲ型電梯,該梯種以集成了變頻控制和邏輯控制的 EV-ECD 01(MCUB)
控制板、SCL 串行通訊系統(tǒng)和 RD-DMS01 變頻門機系統(tǒng)作為電氣的關鍵組成部分,并基本使
用了 GVF-Ⅱ型電梯的機械系統(tǒng)。
資料編寫目的:隨著 GVF-Ⅲ電梯的開發(fā)成功,在工程方面需要提供安裝、調試、維
修和保養(yǎng)各項工作的技術說明。本資料是根據(jù) GVF-Ⅲ電梯的技術特點,列出電梯在工程環(huán)
節(jié)中所需使用的資料,為工程本部編寫 GVF-Ⅲ電梯工程技術資料提供依據(jù)。由于 GVF-Ⅲ
電梯在電氣控制原理上與 GVF-Ⅱ電梯有較多的相同點,又基本使用 GVF-Ⅱ電梯的機械系
統(tǒng),所以本資料對于相同點不再進行敘述,只作出說明“與 XX 電梯保持一致”。
本資料基本內容:
(1) GVF-Ⅲ電梯構成和技術特點。
(2) 安裝部分。電氣回路圖的使用說明;控制柜及轎頂電器箱等重要電氣部分的名
稱、功能介紹;工程大、細線及地線的安裝。
(3) 調試部分。運行前需進行檢查的電梯各項安裝情況,控制柜絕緣測試、低速試
運行、變頻門機的調試運行、層高測定操作、高速運行調試、平層精度調整等。
如有修改意見,請?zhí)顚懜巾摰摹禛VF-Ⅲ電梯調試手冊改進意見表》(復印有效),傳真
或直接交由工程本部工程技術科以作修改。

目 錄
一.GVF-Ⅲ電梯的技術概述··············································5
 1.技術構成及特點··················································5
 2.GVF-Ⅱ與 GVF-Ⅲ的簡單比較········································6
 2.1 機械部分的不同點············································6
 2.2 電氣方面不同部分的簡單比較···································7
 3.GVF-Ⅲ電梯的規(guī)格················································8
二.GVF-Ⅲ電梯機械部分的安裝···········································8
三.GVF-Ⅲ電梯電氣部分的安裝···········································8
 1.電氣回路圖的說明·················································8
 1.1 電氣回路圖的類別和內容·······································8
 1.2 控制柜對外的接線代號及用途···································9
 1.3 電氣回路圖的讀圖方法·········································9
 2.電梯電源參數(shù)····················································11
 3.控制柜概要······················································12
 3.1 控制柜尺寸及主要部件的安裝圖·································12
 3.2 控制柜內部主要部件的名稱和功能·······························14
 4.轎頂電器箱元件布置圖············································15
5.井道內器件、電纜的安裝··········································16
 5.1 井道內器件的安裝與接線······································16
 5.2 井道內電纜的安裝············································16
 6. 廳外召喚箱的安裝、接線及 DIP 開關的設置·························17
 7. 接地線作業(yè)·····················································17
 7.1 控制柜內接地線回路圖········································17
 7.2 系統(tǒng)地線敷線圖··············································18
 8. 其他敷線························································18
四.運行調試···························································19
 1. 運行前準備······················································19
 1.1 運行前檢查·····················································19
1.2 控制柜絕緣測試·················································19
 1.2.1 準備工作··················································19



標記 處數(shù)
 1.2.2 測試方法··················································19
 1.2.3 各回路絕緣標準阻值········································20
 1.3 電壓測試························································21
 1.4 混雜電壓檢查····················································21
 2. 變頻門機的調整···················································22
 2.1 機械調整························································22
 2.2 電氣系統(tǒng)介紹····················································24
 3. 低速試運行······················································26
3.1 開始低速運行····················································26
 3.1.1 通電前準備·················································26
 3.1.2 通電低速試運行·············································26
 3.2 安全回路的確認··················································27
3.3 變頻門機的門寬自檢測············································27
 3.4 變頻門機開關門速度的調整········································27
 3.5 變頻門機的故障檢出··············································28
 4. 高速試運行前檢查和調整··········································28
 5. 高速試運行······················································29
5.1 層高測定························································29
 5.1.1 層高測定運行前的確定······································29
 5.1.2 層高測定的操作順序········································29
 5.2 層高測定前后的軟件確認··········································29
 5.3 高速試運行······················································30
 5.4 電梯對重配置····················································30
5.5 平層調整························································30
 5.6 起動補償調整····················································31
5.7 轎內負荷檢測設置···············································31
 6. 起動舒適感調整··················································32
 7. 功能確認························································32
五.MCUB 板使用說明····················································33
 1. MCUB 板簡介·····················································33



標記 處數(shù)
 2. 小鍵盤介紹·····················································34
 2.1 硬件介紹·······················································34
 2.2 一般操作·······················································34
 2.3 各狀態(tài)解釋·····················································35
六.艾默生變頻器專用操作面板使用說明···································39
1. 操作面板硬件說明················································39
 2. 按鍵功能說明···················································39
3. 指示說明························································40
4. 鍵盤操作說明···················································40
 七.手持編程(GHP)操作說明············································42
 1.手持編程(GHP)硬件說明··········································42
 2.按鍵功能說明·····················································43
 3.GHP 操作流程簡介················································44
八.故障說明···························································44
 1.電梯故障的內部處理方式···········································44
 2.電梯故障代碼表···················································45
 3.變頻器故障代碼表·················································46


文件下載:點擊下載日立GVF-III調試手冊 (點擊查看下載口令
    下載申明:(1)倍加信梯控提供的日立GVF-III調試手冊資料來源于網絡收集整理,并免費提供下載日立GVF-III調試手冊不收取任何費用,若發(fā)現(xiàn)您的權益受到侵害,請立即聯(lián)系我們,我們會立即刪除日立GVF-III調試手冊資料。(2)倍加信梯控提供的日立GVF-III調試手冊資料僅供用戶學習和參考,用戶如果使用下載的日立GVF-III調試手冊資料造成任何損失與倍加信無關,日立GVF-III調試手冊資料最終以版權廠家提供原廠資料為準。(3)倍加信梯控免費提供大量日立電梯技術資料下載,歡迎收藏本站,底部右下角提供了搜索功能,倍加信人臉識別梯控、IC刷卡梯控、二維碼梯控、指紋識別梯控、語音梯控、CPU梯控、ID卡梯控、手機乘梯、機器人乘梯等廣泛應用于日立電梯,歡迎掃碼二維碼加個微信咨詢或備用,再次感謝您在倍加信梯控免費下載日立電梯日立GVF-III調試手冊。